Negative Bias and Increased Variability in VOC Concentrations Using the HydraSleeve in Monitoring Wells

TRRP Training: 2022 Program

presented by: GSI Environmetal Inc.

Texas Risk Reduction Program regulations (TRRP; 30 TAC 350) establish consistent risk-based protocols for assessment and response to soil, groundwater, or surface water impacts associated with environmental releases of regulated wastes or substances.

Presented by GSI Environmental Inc., this popular and informative training series is a must for professionals who need a working understanding of TRRP and those needing to stay up-to-date with the latest TCEQ TRRP guidance and policies.

TRRP Training Course (2 Days): Provides an overview of the TRRP framework and step-by-step training on property assessment and response action procedures established under the TRRP rule

Attendees will become acquainted with rules, key guidance and policies covering affected property assessments, protective concentration levels, and response actions. The course material presents strategies for efficient project management in compliance with TRRP and explains the various report forms adopted by TCEQ.

TAEP image

Sponsored by:
Texas Association of Environmental Professionals (TAEP) TAEP is the premier organization for environmental professionals in the State of Texas. The goals of TAEP include the advancement of the environmental profession and the establishment of a forum to discuss important environmental issues. TAEP members receive a 10% discount. Please call 713.522.6300 for the code.

Dates and Location

Dates

June 14th and 15th, 2022

Location

Crowne Plaza River Oaks 2712 SW Freeway Houston, Texas 77098 713.523.8448 http://www.crowneplaza.com/

Price and Registration

Early-Bird Price

(Paid by May 1, 2022)
$XXX

Standard Price

(Paid after May 1, 2022)
$XXX

TAEP Membership Price

$XXX

Government Price

$XXX
Lodging and meals are not
included in course cost

Published: December 2015 in Groundwater Monitoring and Remediation.

Abstract
The HydraSleeve is a sampling device for collecting groundwater from the screened interval of a monitoring well without purging that uses a check valve to take in water over the first 3 to 5 feet of an upward pulling motion. If the check valve does not perform as expected, then the HydraSleeve has the potential to collect water from an incorrect depth interval, possibly above the screened interval of the well. We have evaluated volatile organic chemical (VOC) results from groundwater samples collected with the HydraSleeve sampler compared to other methods for sampling monitoring wells at three sites. At all three sites, lower VOC concentration results were observed for samples collected using the HydraSleeve. At two of these three sites, the low concentration sample results were most strongly associated with monitoring wells with more than 10 feet of water above the monitoring well-screened interval. At the site with the largest dataset, the median bias for samples collected with HydraSleeve was −20% (p< 0.001). At this site, a bias of −26% (p< 0.001) was observed for the subset of monitoring wells with greater than 10 feet of water above the screened interval compared to a bias of −7% (p= 0.21) for wells screened across the top of the water table. In addition to lower VOC concentrations, the monitoring records obtained using the HydraSleeve were more variable compared to monitoring records obtained using purge sampling methods, a characteristic that would make it more difficult to determine the long-term concentration trend in the well.